Zusammenfassung

This report summarizes relevant available knowledge on the removal of micropollutants from WWTP effluent in natural treatment systems such as constructed wetlands (polishing). Five studies were found investigating removal of various micropollutants in eight different full scale systems located in Spain, southern France, Korea and Sweden (all being different configurations of free water surface wetlands), demonstrating good removal (>80%) for more than 15 micropollutants compounds under summer conditions, e.g. diclofenac, ketoprofen, naproxen, ibuprofen, galaxolide, atenolol, ciprofloxacin, triclosan, glyphosate, ofloxacin and metoprolol. Hydraulic retention times (HRT) ranged from 0.25 to 30d. At HRT of 0.25d, only naproxen and atenolol were removed by >80% in summer, highlighting the importance of HRT for system performance. Another important factor influencing the removal is temperature and season with lower removal in winter. However, in warm climates (e.g. two studies in northern Spain and one study in southern France), reduction of removal efficiencies in winter is less pronounced with values for removal of the majority of investigated pharmaceuticals in winter still being >60%. In 4 FWS wetlands sampled during winter at sub-zero temperatures in Sweden, though, removal was mostly below 50%. A variety of removal mechanisms simultaneously occur in natural treatment systems and are relevant to varying extent for each compound and system type. Important removal mechanisms are biodegradation (e.g. for naproxen, ibuprofen), photodegradation (e.g. for diclofenac, ketoprofen, sulfamethoxazole) and adsorption (e.g. for galaxolide, tonalide). The relevance of plant uptake and phytodegradation as removal mechanisms is not fully understood; however, a few studies demonstrate the translocation of pharmaceuticals (e.g. carbamazepine) to plant tissue. For biodegradation, redox conditions are an important parameter influencing microbial degradation pathways. Design guidelines for eco-engineered treatment systems targeting the removal of micropollutants are not available to date. In addition, data necessary to dimension ecoengineered treatment systems that target the reduction of micropollutants in WWTP effluent (e.g. kinetic data such as removal rates and its dependence on temperature) is lacking. For the development of design guidelines for eco-engineered systems targeting the removal of micropollutants, removal rates for each system type and compound and their dependence from temperatures needs to be determined for all compounds of interest. Furthermore, more research is necessary for a deeper understanding of processes in eco-engineered systems, especially the relevance of the different removal mechanisms and conditions for removal for each individual micropollutant of interest. Nevertheless, eco-engineered treatment systems are a promising technology for polishing of WWTP effluent, including further removal of micropollutants.

Zusammenfassung

The present study provides an overview of geogenic contamination, its occurrence, impacts and possible treatment options for drinking water production. Natural background and anthropogenic contamination can be differentiated using an algorithm based on the frequency distribution of measured substance concentrations. Case studies for geogenic contaminants such as ammonium, fl uoride, chloride, sulfate and uranium are discussed based on the origin, occurrence, controlling factors and treatment options. It is suggested that, in case of occurrence of geogenic contaminants, water must be treated or alternative sources need to be found, e.g., managed aquifer recharge, prior to the distribution as drinking water.

Scheibler, F. , Hannappel, S. , Sprenger, C. , Hartog, N. , Grützmacher, G. , Reger, C. , Huber, A. , Rejman-Rasinska, E. , Hernández-García, M. , Vilanova, E. (2013): Development of a European MAR catalogue.

p 16 In: Managed Aquifer Recharge: Meeting the Water Resource Challenge on Managed Aquifer Recharge (ISMAR8). Beijing, PR China. 15-19 October 2013

Zusammenfassung

In order to efficiently tackle odour problems from sewers which are connected with resident’s complaints and health risks, reliable online odour monitoring is necessary. Multi-gas sensor systems (electronic noses), which display a broad range of odorants, may substitute common online odour monitoring devices in the future. Four electronic noses with different configurations were tested over a period of 8 months at a sewer research plant of Berliner Wasserbetriebe. The objective was to analyse the applicability of four electronic noses for sewer odour management. 11 evaluation criteria were defined to evaluate the E-noses measurement behaviour, stability and their general practicability and handling. Generally it can be mentioned that the results are promising and the E-noses show good potentials. The E-noses which showed good results in predicting the odour concentration at the site have lack of some practical features. Whereas the systems which provide more possibilities (e.g. remote control, direct odour display) and have more complex gas preparation or measurements modes (like thermal desorption) showed lower capabilities to measure the actual odour at the site.

Uldack, M. (2013): Modelling the impacts of combined sewer overflows on the Berlin River Spree.

Master Thesis. Fakultät III Prozesswissenschaften, Institut für Technischen Umweltschutz. Technische Universität Berlin

Zusammenfassung

Combined sewer overflows (CSO) after heavy rainfall can cause acute depletions of dissolved oxygen (DO) in the Berlin River Spree. A planning instrument for CSO impact assessment has been developed in the framework of the research project MIA-CSO at the Kompetenzzentrum Wasser Berlin. This instrument couples the sewer model InfoWorks CS, the water quality model Hydrax/QSim and an impact assessment tool. Within this thesis it is tested for various CSO management strategies and climate change scenarios. The coupled sewer-river-model InfoWorks CS-Hydrax/QSim was validated for the years 2010 and 2011. Simulation results for the critical parameters discharge and DO concentrations in the Berlin River Spree agree well with measurements. Although not all observed DO deficits can be simulated accurately, the very good representation of processes related to the oxygen budget allows assessing relative changes in boundary conditions, e.g. from different CSO control strategies. The conducted scenario analysis indicates that the coupled sewer-river-model reacts sensitively to changes in boundary conditions (temperature, rainfall, storage volume and other CSO control strategies, etc.). Based on the simulation year 2007 - representing an extreme year with regards to CSO volume and critical conditions in the river - sewer rehabilitation measures planned to be implemented until 2020 are predicted to reduce total CSO volumes by 17% and discharged pollutant loads by 21-31%. The frequency of critical DO conditions for the most sensitive local fish species (<2 mg/L) will decrease by one third. For a further improvement of water quality after the year 2020, the reduction of impervious surfaces emerges as a very effective management strategy. A reduction of the impervious connected area by 20% results in a decrease in the frequency of critical DO conditions by another third. The studied increase in surface air and water temperature as part of the climate change scenarios leads to a significant aggravation of DO stress due to background pollution in the Berlin River Spree, while acute DO depletions after CSO are barely affected. However, changes in rain intensity have a considerable effect on CSO volumes, pollutant loads and the frequency of critical DO concentrations. The extended sensitivity analysis shows that a general reduction of discharged pollutant loads by 60% based on the sewer status 2020 can prevent critical DO conditions in the Berlin River Spree, even for the exceptionally rain intense year 2007. Further, it has been shown that the entry and biodegradation of organic carbon compounds is the most important process for acute DO depletions after CSO. However, mixing of oxygen free spill water with the Berlin River Spree provokes an additional impairment of DO conditions. In the framework of this thesis, CSO impacts under different management strategies or climate change conditions are only assessed for a part of the Berlin combined sewer system and for one exemplary year. Before applying the presented instrument for planning specific measures it is proposed to expand the model area and simulated time period.

Stevens, D. (2013): Geological CO2 storage and shale gas exploitation: Monitoring methods to be used for at the different project phases.

Master Thesis. École nationale supérieure d'électrotechnique, d'électronique, d'informatique, d'hydraulique et des télécommunications

Zusammenfassung

Within the context of continuously increasing CO2 concentrations in the atmosphere, as well as diminishing reserves of fossil fuels, finding new ways for autarkic and “climate friendly” energy production becomes more and more important. The development of emerging subsurfaces activities like Carbone Capture and Storage, and Hydraulic Fracturation might offer new options to tackle all three of the mentioned challenges. But, carbon capture and storage (CCS) and unconventional gas exploration (“hydro-fracking”) have in common that they impact parts of the subsurface and may thus potentially have an effect on fresh water aquifers. The combination of all the most recent studies about GCS and Hydro-fracking, allows the identification of a broad panel of key parameters that can assess and indicate a groundwater contamination resulting from emerging subsurface activities. Strong emphasis needs to be put on the fact that numerous new monitoring, verification and accounting tools are being developed worldwide threw researches programs. However, actually, it seems that the most efficient monitoring and early warning network should be based on the combined used of the most suitable (site-specific) geophysics and geochemicals tools.

Warneke, J. (2013): Screening of different sewage sludge disposal routes regarding the energy demand with focus on hydrothermal carbonisation.

Master Thesis. Energy Process Engineering and Conversion Technology for Renewable Energies. Technische Universität Berlin

Zusammenfassung

The goal of this study is to analyze whether the integration of a Hydrothermal Carbonization (HTC) process into sewage sludge disposal routes improves the holistic energy balance compared to state of the art technologies. Furthermore the decisive parameters for the improvement are identi ed. For this a static model is set up within the energy and material flow calculation software Umberto. Within the selected treatment scenarios without and with anaerobic digestion the Cumulative Energy Demand (CED) and Global Warming Potential (GWP) are determined per functional unit disposal of one kg TSsludge. The model is fed with full-scale data from state of the art sludge treatment and data of a pilot HTC plant. It comprises all relevant processes including their chemicals and energy demands as well as transportation of materials. Expenditures for infrastructure are excluded. The reference input flow is based on the annual sludge amount of a waste water treatment plant for 500,000 people equivalents. The final disposal options of the sludge or hydrochar are either co-incineration within a lignite power plant or mono-incineration. Some co-products such as electricity, biomass fuel (dried sludge, hydrochar) and nitrogen fertilizer are created during sludge treatment and accounted for as substitutes for production of equivalent resources. HTC distinguishes from the conventional sludge treatment by improved mechanical dewaterability of the products. It reaches dry matter contents of ~ 65%. Trade-offs are the significant process heat demand of 88kWh/m3 sludge at high temperatures > 220 °C and a decreased mass yield of 72 % for the undigested and 75 % for the digested sludge. The dry matter loss results in process liquor with multiple load compared to raw sludge liquor (80 x org. C, 60 x Ntot, 25 x Ptot). The CED and GWP results generally show good correlation. For the CED of raw sludges the net values range from savings of -11.7 to expenditures of +1.8MJ/kg TS. The GWP ranges from -1.07 to +0.43 kg CO2-eq/kg TS. The net values for the HTC scenarios exceed the reference scenarios for undigested sludge when the dry matter content after sludge dewatering is < 27% or if it is ~ 27% and the process heat demand of the HTC can be reduced by half e.g. via insulation. However, the best scenario for undigested sludge includes HTC with a small scale digester only for the liquor. The loads are largely reduced, saving energy for the return ow treatment and producing biogas for use in a CHP plant. The heat can be fed to the HTC reactor while grid electricity is substituted. In disposal routes including sludge digestion the CED ranges from -11 to -1.1MJ/kg TS and the GWP ranges from -0.73 to +0.22 kg CO2-eq/kg TS. The scenarios with HTC exceed the reference scenarios irregardless of the TS after dewatering. The HTC liquor is returned to the digester, reducing the load and yielding extra biogas as mentioned above. Also, with sludge digestion the HTC process benefits from the larger amount of CHP heat. It is sufficient to cover the heat demand within the analyzed scenarios. The reference sludge treatment is based on representative full-scale data, but the pilot plant data of HTC showed inconsistencies. The data has to be validated in full scale. Furthermore, important aspects such as refractory COD within the hydrochar liquor, pollutants such as heavy metals, legal aspects of the hydrochar incineration, nutrient recovery and economic aspects have to be addressed in future studies.

Matzinger, A. , Mutz, D. , Uldack, M. , Remy, C. , Rouault, P. , Pawlowsky-Reusing, E. , Gnirß, R. , Lemm, K. , Bartholomäus, C. , Draht, K. , Keller, S. (2013): Maßnahmen zur Reduktion der Nährstoffeinträge urbaner Standorte.

p 13 In: 29. Jahrestagung der Deutschen Gesellschaft für Limnologie e.V. (DGL). Potsdam, Germany. 9-13 September 2013

Dr. Hella Schwarzmüller , Menz, C. (2013): WELLMA-2 Synthesis report.

Kompetenzzentrum Wasser Berlin gGmbH

Zusammenfassung

Objective of this synthesis report is to summarize the main achievements of the WELLMA-2 project. Based on the preparatory phase WELLMA-1 (2007-2009), the main project phase WELLMA-2 (2009-2012) included extensive laboratory, pilot-scale and field site investigations aiming at optimizing the operation and maintenance of drinking water production wells with respect to costs, energy efficiency and sustainability. The main reason for inefficient well performance is so-called well ageing. Deposit formation due to multiply correlated biological, chemical and/ or physical clogging processes in and around the well cause a decrease in performance. Thus, the interdisciplinary WELLMA-project team aimed at improving the efficiency of drinking water production wells by providing a scientific basis to support operators in their efforts to reduce well ageing. This included the development of guidance and recommendations for an adapted and well-planned operation scheme and maintenance strategy to sustain or reinstall the well performance. Well ageing processes were intensively studied at a multitude of vertical drinking water production wells located in Berlin, Germany and near Bordeaux, France. Thereby, classical monitoring and diagnosis methods, such as pumping tests and TV inspections, but also newly developed own experimental setups, such as the in-situ measurement of oxygen, depth-oriented water sampling or the exposure of object slides and bio-reactors for biofilm growth were applied. This synthesis report follows the project outline featuring four work packages dealing with (i) the identification of ageing types and the site-specific ageing potential from optimal data processing of site and well characteristics to provide decision support for the diagnosis and subsequent optimisation of well operation, monitoring and maintenance, (ii) field methods and experimental setups applied within the WELLMA-project to investigate mixing processes, oxygen uptake and biofilm formation, (iii) the impacts of intermittent operation on the uptake potential and distribution patterns of oxygen, and (iv) the efficiency of hydrogen peroxide treatments for preventive well maintenance against biochemically induced iron ochre formation and the oxygen uptake potential correlated to the decomposition of H2O2. Intermediate data were presented at various occasions at scientific and practiceoriented conferences, e.g. the Association for General and Applied Microbiology (VAAM), the International Water Association (IWA) Groundwater conference, International Association of Hydrogeologists (IAH), Berlin-Brandenburger Brunnentage, Wasser Berlin etc. and in related papers. A publication list is given at the end of this synthesis report.

Möchten Sie die „{filename}“ {filesize} herunterladen?

Um unsere Webseite für Sie optimal zu gestalten und fortlaufend verbessern zu können, verwenden wir Cookies. Durch die weitere Nutzung der Webseite stimmen Sie der Verwendung von Cookies zu. Weitere Informationen zu Cookies erhalten Sie in unserer Datenschutzerklärung.